J-400 Series

11.0 Programming Instructions

11.1 Programming Filter/Circulation Pump Run Time
The Sentry control system allows you to easily adjust two separate aspects of
filter/circulation pump operation:

1. The time of day (start time) the filter/circulation pump turns on.
2. The length of time (duration) the filter/circulation pump operates.

The factory default start time is 12:00AM (Midnight). The default duration is 24
hours. To make adjustments, press the CYCLE

button to enter the filter/

circulation pump programming mode.

“Circ” appears on the LCD. Now, the

system is ready to accept your changes:

• Press the SELECT

button once. The previously programmed

start time appears on the LCD display.

• Press WARMER

or COOLER

buttons to adjust the start

time in 30-minute increments.

• Press the SELECT

buttons to program duration.

• Press WARMER

or COOLER

buttons to program the

duration time in 1 hour increments.

• Press DISPLAY

button to save changes and recall the main water

temperature display. Note: If no button is pressed within 30 seconds, all
changes are recorded and the screen automatically returns to the standard
water temperature display.

Note: When the standard mode is selected (sec. 10.3, page

34

), the filter/circu-

lation pump automatically turns on for a heat call regardless of the pump’s
programmed start time and duration.

11.2 Programming Filter Cycles
Your spa comes with four 30-minute filter cycles which activate the filter/circu-
lation pump. These cycles are factory programmed to start at 6:00 am, 12:00
p.m., 6:00 p.m., and 12:00 a.m. The control system allows you to easily adjust
two separate aspects of each cycle: 1) the time of day at which it begins; 2) the
duration of the cycle.

Note: When “Standard” mode is selected (sec. 10.3, page

34

) and the filter/circu-

lation pump is set to the factory default duration of 24 hours (sec. 11.1), no
apparent change of operation will occur. However, when “Economy” mode is
selected (sec. 10.3, page

34

), the heater activates only during a programmed filter

cycle.