15.0 Troubleshooting - Procedures

In the unlikely event your spa is not working the way you believe it should,
please first review all the installation and operating instructions in this manual
and check the message on the panel display; second, if you are still not satis-
fied it is working properly, please follow the appropriate troubleshooting
instructions.

PROBLEM

PROCEDURE

NONE OF THE
COMPONENTS
OPERATE (i.e.
pump light)

Check the control panel lights.
1. If there are letters or symbols displayed on the

screen, refer to the previous section to determine
the meaning and action required.

2. If nothing appears on the screen:

a. Check the household circuit breaker

b. Contact you dealer or authorized service center

PUMP DOES NOT
OPERATE AND
ICON DOES

Depress “JETS” button.
1. If no sound is detected or if a “buzzing” sound AND

ICON DOES is detected, turn off power to the spa
and contact your dealer or service center.

2. If motor operates but no water flows to jets:

a. Pump may not be properly primed. See instruc-
tions below.

b. Contact dealer or authorized service center.

Pump Priming Instructions:
1. Turn off power to the spa.
2. Remove the handle from the massage selector supplied by the pump you are

priming.

3. Loosen the massage selector’s cap slightly (counterclockwise), listening for

the air to seep out.

4. Tighten the cap finger-tight, replace the handle and turn the hot tub’s power

back on.

Note: This method must be used for the jet’s pumps because these pumps are not
connected to the main filter system in any way.

CAUTION: If freezing conditions exist and pump is not operational,
take measures to protect the system from freeze damage. See section
titled “Winterizing” (page