Loading library firmware – Spectra Logic 10000 User Manual

Page 69

Advertising
background image

Chapter 5. Operating the Library

69

Loading Library Firmware

1.

If a tape is present in Drive 1, unload it from the drive.

2.

From the main screen, select Menu > Miscellaneous > Load Firmware. The Code
Tape screen appears (Figure 5-5) and returns the following message:

WARNING: This changes your firmware!
Abort to keep current code. Press OK to continue.

Note:

Before proceeding with the firmware upgrade, you must have:

A Spectra Logic firmware upgrade tape

A backup code tape on hand (see Creating a Backup Firmware
Tape on page 67
).

3.

Insert the upgrade or backup firmware code tape into the door slot, then touch
OK. The library loads the tape into Drive 1.

If the tape is valid, the screen displays the following additional information:

*** KEEP POWER ON UNTIL FINISHED! ***
Rewinding
Reading Header
Version of code on tape is #.##.##
Reading Firmware
CRC: ####
Rewinding
Current Code Version is #.##.##
Press OK to load new version, else Abort.

Figure 5-5 The Code Tape screen.