7ML19985BE02

SITRANS LU01 – INSTRUCTION MANUAL

Page 51

m

mmmm

Pa
ra

m

e

te

rs

P302 Temperature, Sensor Maximum

View the highest temperature encountered, as measured by the TS-3 Temperature

Sensor (if applicable).

Press CLEAR

keys to reset the log after a short circuit on the transducer wiring.

Profile Records (P330 to P337)

These features can record up to ten Echo profiles, initiated manually (P330), or
automatically (P331 et al) for viewing at a later time using Dolphin Plus or an oscilloscope.
See

Scope Displays (P810) for echo profile viewing hardware / software requirements. If

ten Profiles are already saved, addresses 1 through 10 are filled, the oldest automatically
initiated record is overwritten. Manually initiated records are not automatically
overwritten. All records are automatically deleted in the event of a power interruption.

When a record is displayed, results are based on current programming (which may have
been altered since the record was saved). This permits the effect on the echo profile to be
observed when changing an echo parameter.

P330 Profile Record

Records profiles for later viewing.

In addition to being a profile records library, this provides two functions:

manually records and saves echo profiles

displays an echo profile, recorded manually or automatically (oscilloscope)

To select a record address

1.

Enter PROGRAM mode and press DISPLAY

twice to highlight the index field.

The field shows two underscores _ _.

2.

Type the index number. The profile record information is shown.

3.

Use ARROWS

to scroll through the records.

Values

Range: - 50 to 150°C (view only)
Preset: - 50°C

WARNING:

These parameters are for authorized service personnel or

technicians familiar with Siemens Milltronics echo processing techniques.

Primary Index

Echo profile

Values

Code

Description

----

no record

A1

automatically recorded profile from Transducer One

U1

manually recorded profile from Transducer One