Chapter 2

Powering the OXF-R3

Chapter 2 Powering The OXF-R3

2-1 OXF-R3 Start-Up Procedure

CAUTIONS:

1. Before starting up the OXF-R3, check that all Monitor

Loudspeaker Power Amps are turned off or muted.

2. Switch on equipment in the sequence given here, to ensure trouble-

free start-up.

2-1-1 Start-Up Procedure

1. Check that the motionworker and Lynx Time Code Module are already

switched on and running normally.

2. Switch on the power to the SP Rack.

3. Switch on the power to the Host Computer.

4. Switch on the power to the I/O Racks.

It is important that the I/O racks are switched on in the sequence of the Sync
Clock wiring loop connected to the clock inputs of the I/O Racks.

5. The Host Computer performs its start-up and self-test routines. At the

end of these routines, a triple chevron prompt >>> should be displayed
on the monitor.

6. Type b then press {RETURN} to start the boot-up process for the

OXF-R3 system.

If your Host Computer has been configured for Auto-boot (an option at set-up),
the triple chevron prompt will not be displayed and boot-up will proceed
automatically.

7. At the end of the boot-up procedure, the Login field will be displayed

on the monitor.

8. Now switch on the power to the control panel. All 7 LCD screens will

show activity as programs are downloaded from the Host Computer to
the computers within the console. When downloading is completed,
an ‘X’ is displayed in the centre of each screen.

Note:

Note:

2-1 OXF-R3 Start-Up