Owner’s Manual - Regal Intensive Care Unit

34 - Oxygen Port to

Filter/Fans

Compartment

After leaving the oxygen flow meter, oxygen is directed through
plastic tubing to this port in the partition wall between the electron-
ics compartment and the filter/fans compartment (Figure 26). The
oxygen is injected into the airflow after it passes through the Soda-
lime filter, and is then carried to the animal compartment in the
circulating air. Also, refer to Figure 29.

Figure 26. Main Terminal Block, Oxygen Sensor/Fuel Cell,and Oxygen Port to Filter/
Fans Compartment

Temperature

Sensor Mount

32 - Oxygen

Sensor/Fuel Cell

23 - Oxygen Flow
Meter & Solenoid

Oxygen Line to
Flow Meter

34 - Oxygen Port to

Filter/Fans
Compartment

Oxygen Line to
Filter/Fans
Compartment

32 - Main Terminal

Block