Owner’s Manual - Regal Intensive Care Unit

Latch Connector

P/N 212047

There is one latch connector on each animal compartment door. The
two latch connectors are identical and are removed and installed
the same way. The latch connectors can be replaced without
removing the doors from the unit.

Tool Required

„

Phillips screwdriver

Removal

1.

Open the door so that the latch connector is completely
dis-engaged from the top and bottom latch brackets.

2.

With a Phillips screwdriver, remove the two cap screws that
secure the bottom latch connector holder (Figures 86
and 87) and remove the holder from the unit.

3.

Remove the two cap screws that secure the top latch
connector holder and remove the holder and the latch
connector from the door.

Installation

1.

Hold the latch connector and the top latch
connector holder in place on the door and
secure with the two cap screws.
Note: The locating pins in the latch
connector (Figure 86) should ride above
the top latch connector holder, and under
the bottom latch connector holder.

2.

Secure the bottom latch connector in place
with the two cap screws.

3.

Try closing and latching the door several
times to make sure the latch connector
operates correctly.

Figure 87. Latch Connector & Holders

Latch

Connector

Latch

Connector

Holders