Product properties

3.28 Displays

SCALANCE X-200

124

Operating Instructions, 12/2011, A5E00349864-19

3.28.4

Redundancy manager indicator (green LED)

Redundancy manager indicator (green LED)

The LED signals that the IE Switch X-200 can adopt the following statuses:

Device type SCALANCE

LED lit green

LED flashes green

LED not lit

XF204

1

2

3

X208

1

2

3

XF208

1

2

3

X216

1

2

3

X224

1

2

3

X204-2

1

2

3

X204-2TS

1

2

3

XF204-2

1

2

3

X206-1

1

2

3

XF206-1

1

2

3

X212-2

1

2

3

X204-2LD

1

2

3

X206-1LD

1

2

3

X212-2LD

1

2

3

X202-2IRT

1

2

3

X204IRT

1

2

3

XF204IRT

1

2

3

X204 IRT PRO

1

2

3

X202-2P IRT PRO

1

2

3

X201-3P IRT PRO

1

2

3

X202-2P IRT

1

2

3

X201-3P IRT

1

2

3

X200-4P IRT

1

2

3

1. The device is redundancy manager. The ring is closed.
2. The redundancy manager has switched over. The ring is interrupted.
3. The redundancy manager is disabled.

Note
The status of the redundancy manager and standby are displayed as a double function

by a single multicolor LED. This is identified on the device by RM.
It changes its color depending on the function (redundancy function -> green, standby

function -> yellow).
In Web Based Management, the LED is labeled differently depending on the function

(redundancy function, basic status -> label RM, standby function -> label SB).