Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 26

Advertising
background image

Network topologies / media redundancy

2.4 MRP

SCALANCE X-200

26

Operating Instructions, 12/2011, A5E00349864-19

Topology

The following schematic shows a possible topology for devices in a ring with MRP.

10

9

8

7

6

5

4

3

2

1

5HGXQGDQF\GRPDLQ

+0,VWDWLRQ

(QJLQHHULQJVWDWLRQ

(76

(70

(7SUR

6ZLWK&3$GYDQFHG

6&$/$1&(;VZLWFK

3&ZLWK&3

6ZLWK&3$GYDQFHG

Figure 2-9

Example of a ring topology with the MRP media redundancy protocol

The following rules apply to a ring topology with media redundancy using MRP:
● All the devices connected within the ring topology are members of the same redundancy

domain.

● One device in the ring is acting as redundancy manager.
● All other devices in the ring are redundancy clients.
Non MRP-compliant devices can be connected to the ring via a SCALANCE X switch or via

a PC with a CP 1616.

Note

SCALANCE X-300 - modular devices (M)
Remember that in the modular switches the ring ports are located on MM900 media

modules.