Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 186

Advertising
background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

186

Operating Instructions, 12/2011, A5E00349864-19

Figure 6-20 Ring Redundancy WBM menu (if the device is operating as a ring client)

Enable ring redundancy

Here, you can choose whether or not the module is part of a ring.
Redundancy Mode

Here, you can choose the role of the module within a ring.
● Automatic Redundancy Detection

Select this setting to configure the redundant mode automatically.

In "Automatic Redundancy Detection" mode, the IE Switch X-200 automatically detects

whether or not there is a device with the role of "HSR Manager" in the ring. If this is the

case, the device adopts the role of "HSR Client".

If no HSR manager is found, all devices with the "Automatic Redundancy Detection"

setting negotiate among themselves to establish which device adopts the role of "MRP

Manager". The other device automatically set themselves to "MRP Client" mode.

● MRP Client

Here, you can select the "MRP Client" role.

In an MRP ring, at least one device must be set either to the mode "Automatic

Redundancy Detection" or to the mode "MRP Manager (Auto)/Client". You also have the

option of setting the "MRP Client" role for all other devices. If all except one device in the

ring is configured as "MRP Client", this device automatically adopts the role of "MRP

Manager".

Select "MRP Client" mode if you want to operate the device along with components that

do not originate from Siemens in the ring.

Advertising