Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 214

Advertising
background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

214

Operating Instructions, 12/2011, A5E00349864-19

Negotiation

Indicates whether autonegotiation is enabled or disabled.
Status

Indicates that the port is enabled.
Link

Status of the link to the network. The following alternatives are possible:
● up

The port has a valid link to the network, a link integrity signal is being received.

● down

The link is down, for example because the connected device is turned off.

NOTICE

With IE Switches X-200, that are not IRT-compliant, it is not possible to disable ports in

PROFINET mode!
If a port of such a device is disabled by Web Based Management, the disabled setting is

overwritten when a PROFINET configuration is downloaded. In PROFINET mode, all

ports of a non IRT-compliant IE Switch X-200 are automatically enabled.

Note
If an IE switch port operating in autonegotiation mode is connected to a partner device that is

not operating in autonegotiation mode, the partner device must be set permanently to half

duplex mode.
If an IE switch port is set permanently to full duplex, the connected partner device must also

be set to full duplex.
If the autonegotiation function is disabled, the MDI/MDI-X autocrossover function is also

inactive. This means it may be necessary to use a crossover cable.

Syntax of the Command Line Interface

Table 6- 24 Switch Port Status - CLI\SWITCH>

Command

Description

Comment

ports

Displays the port status.

Administrator only.

Table 6- 25 Switch Ports Status - CLI\SWITCH\SETPORT>

Command

Description

Comment

info

Displays the current port settings.

enable <port> [D ¦ E]

Enables / disables the specified port.

Administrator only.

Advertising