Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 210

Advertising
background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

210

Operating Instructions, 12/2011, A5E00349864-19

● SIMATIC time

If you use the SIMATIC time transmitter, you do not need to make any further settings.

● Manual

Here, an input field opens for you to enter the current time. The time is quartz controlled

and thus always exact. When you switch off or reset the device, this information is lost

and must be entered again.

Time zone offset

You can enter a time zone correction for the SNTP protocols here.
Time server

Here, you can enter the Internet address of the server with which the system time will be

synchronized. The number of the UDP port being used can also be entered. As default, the

SNTP protocol uses UDP port 123.
Init poll interval

Here, you can enter the interval at which the IE Switch X200 repeats the initial poll for the

system time if this was not successful the first time.
Poll interval

Once the system time has been adopted the first time from the time server, it is updated

cyclically with renewed polls to the time server. Here, you specify how often the updates take

place.

Syntax of the Command Line Interface

Table 6- 22 Agent Time Client Configuration - CLI\AGENT\TIME>

Command

Description

Comment

info

Displays information on the time

settings of the IE switch.

timec [E ¦ D]

Enables / disables the time

settings of the IE switch.

Administrator only.

server [IP address] [:port]

Sets the IP address and the port

of the server.

Administrator only.

tzone [-12..+12]

Sets the time difference in hours

between the server and system

time.

Administrator only.

tinitpoll [1000-100000ms]

Specifies the polling interval …? Administrator only.

tpoll [10-100000s]

Specifies the polling interval in

the range from 10 - 100000 s.

Administrator only.

ttype [P ¦ L ¦ S ¦ M]

Specifies how the time is set:

- P SNTP poll

- L SNTP listen

- S Siemens

- M manual.

Administrator only.

settime [time]

Sets the time manually

(DD MMM HH:MM:SS YYYY).

Administrator only.

Advertising