Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 171

Advertising
background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19

171

Restart System

Click this button to restart the IE Switch X-200. You must confirm the restart in a dialog box.

During a restart, the IE Switch X-200 is reinitialized, the internal firmware is reloaded. The

learned entries in the address table are deleted. You can leave the browser window open

while the IE Switch X-200 restarts.
Memory Reset and Restart

Click on this button to restore the factory configuration settings with the exception of the

following parameters:
● IP address
● Subnet mask
● IP address of the default router
● DHCP flag
● System name
● System location
● System contact
● PNIO Device Name
● System Event Log Table
● Settings for ring redundancy and standby
An automatic restart is triggered. In the user mode, this button is invisible.
Restore Factory Defaults and Restart

Click this button to restore the factory defaults for the configuration. The protected defaults

are also reset. In the user mode, this button is invisible.

Note
The IE Switch X-200 must be given a new IP address before it can be accessed again.

Syntax of the Command Line Interface

Table 6- 5

System Restart & Defaults - CLI\SYSTEM\RESTARTS>

Command

Description

Comment

memreset

Restores the factory defaults.

The protected settings are

retained.

Administrator only.

defaults

Restores the factory defaults.

The protected settings are also

reset.

Administrator only.