Technical specifications – Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 277

Advertising
background image

Technical specifications

SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19

277

Table 10- 3 Electrical data

Device type

SCALANCE

Power supply

2 x 12 ... 24 VDC

(10 ... 30 VDC)
SELV (Safety Extra

Low Voltage)

Power loss at 12 VDC Current consumption

at rated voltage

Overcurrent protection at

input

Non-replaceable fuse (F)

X204-2TS

+

6.60 W

0.6 A

3.0 A / 32 V

Device type

SCALANCE

Power supply

2 x 24 VDC
(18 ... 32 VDC)
SELV (Safety Extra

Low Voltage)

Power loss at 24 VDC Current consumption

at rated voltage

Overcurrent protection at

input

PTC resettable fuse

XF204

+

2.64 W

110 mA

1.1 A / 33 V

X208

+

3.84 W

160 mA

0.6 A / 60 V

XF208

+

3.12 W

130 mA

1.1 A / 33 V

X216

+

5.76 W

240 mA

1.1 A / 33 V

X224

+

8.40 W

350 mA

1.1 A / 33 V

X204-2

+

6.36 W

265 mA

0.6 A / 60 V

XF204-2

+

5.28 W

220 mA

1.1 A / 33 V

X206-1

+

5.28 W

220 mA

0.6 A / 60 V

XF206-1

+

4.08 W

170 mA

1.1 A / 33 V

X212-2

+

7.92 W

330 mA

1.1 A / 33 V

X204-2LD

+

6.36 W

265 mA

0.6 A / 60 V

X206-1LD

+

5.28 W

220 mA

0.6 A / 60 V

X212-2LD

+

7.92 W

330 mA

1.1 A / 33 V

X202-2IRT

+

6.0 W

300 mA

0.6 A / 60 V

X204IRT

+

4.8 W

200 mA

0.6 A / 60 V

XF204IRT

+

4.8 W

200 mA

0.6 A / 60 V

X204 IRT PRO

+

4.8 W

200 mA

0.6 A / 60 V

X202-2P IRT PRO

+

7.2 W

300 mA

1.1 A / 33 V

X201-3P IRT PRO

+

7.2 W

300 mA

1.1 A / 33 V

X202-2P IRT

+

7.2 W

300 mA

1.1 A / 33 V

X201-3P IRT

+

8.4 W

350 mA

1.1 A / 33 V

X200-4P IRT

+

9.6 W

400 mA

1.1 A / 33 V

Advertising