Port indexes – Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 240

Advertising
background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

240

Operating Instructions, 12/2011, A5E00349864-19

Table 6- 37 Variables in the Interface directory

Variable

Access rights

Description

ifNumber

Read only

The number of different interfaces available in the component.

Possible values: 4 - 8

ifDescr

Read only

A description and possibly additional information for a port. Possible

value: string with a maximum of 255 characters

ifType

Read only

The value ethernet-csmacd(6) or optical(65) is entered for

SCALANCE X-200.

ifSpeed

Read only

Data transfer rate of the Ethernet port in bits per second. With

SCALANCE X-200 devices, this is either 10 Mbps or 100 Mbps

ifOperStatus

Read only

The current operating status of the Ethernet port. The following values

are possible: ● up(1) ● down(2)

ifLastChange

Read only

Length of time for which the selected port has been operating in the

current status. The value is shown in hundredths of a second.

ifInErrors

Read only

Number of received packages that were not forwarded to higher protocol

layers because of an error.

ifOutErrors

Read only

Number of packages that were not sent because of an error.

Port Indexes

The interface index must be used for port designations. The following table shows how the

interface indexes are assigned to the ports.

Interface Index

Port

1

Port 1

2

Port 2

3

Port 3

4

Port 4

5

Port 5

6

Port 6

7

Port 7

8

Port 8

.

.

.

.

.

:

24

Port 24

Important private MIB variables of an IE Switch X-200

OID The private MIB variables of the IE Switch X-200 have the following object identifier:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).

ad(4196).adProductMibs(1).simaticNet(1).iScalanceX(5).iScalanceX200(2)