Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

206

Operating Instructions, 12/2011, A5E00349864-19

Syntax of the Command Line Interface

Table 6- 20 Agent Event Configuration - CLI\AGENT\EVENT>

Command

Description

Comment

info

Shows the current event configuration.

scontrol [C|A].

Selects how the signaling contact works:

Conventional

An error/fault is displayed by the LED and
the signaling contact opens.

Aligned

The signaling contact can be opened or
closed as required regardless of a
fault/error.

Administrator only.

sclose [yes|no]

Switches the signaling contact, if this in

"aligned" mode:

Yes

The contact is closed.

No:

The contact is opened

Administrator only.

Specifies how an IE switch reacts to system

events. You can enter the following values for

the <Event> parameter:
CW

Cold/Warm Start

LC

Link Change

AF

Authentication

Failure

PM

Power M12

Change

FC

Fault State Change

RD

Redundancy Event

SB

Standby Event

setec

<Event> <Index> <E|D>

<E|D> <E|D>

LD

Loop Detection

Administrator only.

If an event is specified, the configured

actions are formed for each event.
The three parameters <E> or <D> configure

the reactions of the IE switch in the order:

E-mail

Trap

Entry in the log table

Example: If you only want to send an E-mail

when there is a Link Change, enter the

following command:

setec LC E D D