Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 208

Advertising
background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

208

Operating Instructions, 12/2011, A5E00349864-19

SMTP Server IP Port

The IP port over which the mail is sent. If necessary, you can change the default value 25 to

your own requirements in the CLI.
"From" Field
You can enter a text that appears in the "From" field of the E-mail.
Send Test E-Mail

Sends an E-mail with the selected parameters.

Syntax of the Command Line Interface

Table 6- 21 Agent E-Mail Configuration - CLI\AGENT\EMAIL>

Command

Description

Comment

info

Shows the E-mail configuration.

mail [E ¦ D]

Enables/disables the mailing

function.

Administrator only.

smtp [IP address] [:port]

Specifies the IP address and the

port number of the SMTP

server.

Administrator only.

from [address]

Specifies a text that will be

entered in the "From" field of the

E-mail.

Administrator only.

email [E-mail address]

Specifies the address to which

an IE switch sends an E-mail.

This address can be up to a

maximum of 50 characters long.

Administrator only.

testmail <test E-mail comment> Sends an E-mail for testing.

Administrator only.

Advertising