Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 158

Advertising
background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

158

Operating Instructions, 12/2011, A5E00349864-19

Starting Web Based Management and logging on

1. Enter the IP address or the URL of the IE switch in the address box of the Web browser.

If there is a problem-free connection to the IE switch, the Logon dialog of Web Based

Management is displayed:

Figure 6-5

LOGON screen

2. In the "User Name" list box, select the "Admin" entry if you want to change settings of the

IE switch (read and write access). If you select the "User" entry, you only have read

access to the configuration data of the IE switch.

3. Enter your password. If you have not yet set a password, the default passwords as

shipped apply: Enter admin if you selected "admin" as the user name or user if you

selected "user".

Note

For security reasons, make sure that you change the original factory-set passwords.

Resetting the device also resets the passwords to the factory settings.

4. Click the "Log On" button to start the logon.

Advertising