2-3 (3) Setup for

“Tow Rooms (Independent) Operation”

of X700P Manager GUI

(A) SETUP of Main X700P for “SCENE MEMORY-1”

To open ROUTING SCREEN of the Main X700P

To assign line sources to the
Front Speakers.
No assignment of mic signals
for less feedback.

No assignment to the Satellite
Speakers to avoid routing
sound of the main system to
sub system area.

The OUTPUT-7 is assigned to
rout mic signal to internal 70V
line amplifier. No assignment
of line sources and MIC-5&6.

No assignment of mic sources
to the sub system because of
the “2-room Operation”.

Assignment of mic except for MIC-5&6 and line sources except for MD source, to a recorder (MD).
The MIC-5 & 6 are not assigned to avoid picking up because the two microphones are located on the area of sub system.
The MD source is not assigned to the MD recorder to avoid feedback caused by loop during recording.
Instead of this assignment, mic signals are only assigned to RECOUT-1 (L channel of MD), line sources are only done to
RECOUT-2 (R of MD), for clearer sound quality when played back.

To open OUTPUT SCREEN of the Main X700P

To select 70V LINE on the MODE box. (In case of selecting
the 70V LINE, CH 2 box is closed because 70V operation
makes the internal amplifier be MONO).

To select OUTPUT7 on the SELECT box. Attenuation is set
by adjusting sound level of listening area. No MUTING.

To open OUTPUT SCREEN of the Main X700P

(b) To select 1 for SCENE No.
And memo about operation, etc.

(c) To check buttons including
ROUTING at least.

(d) To press button of STORE.

(a) To avoid inadvertent operation, scene recall buttons of front

panel are not recommended to use. The Control Box is

recommended to recall.

The INFORMATION box may be used to provide more detailed information.
(There is not a separate INFORMATION box for each SCENE MEMORY.)

If the “Independent Operation” is
mainly used, the SCENE No1 is
selected on Power On Setting box.

Advertising