IMPORTANT SAFETY INSTRUCTIONS

WARNING: When using electrical

products, always follow basic

precautions, including the following:
DANGER: Risk of electrical shock.

Connect only to a circuit protected by a

GroundĆFault CircuitĆInterrupter (GFCI).

A pressure wire connector is provided on the

exterior of the pump or control within this unit to

permit connection of a bonding conductor

between this unit and all other exposed metal in

the vicinity, as needed to comply with local

requirements.

To reduce the risk of electric shock, connect only

to a properlyĆgrounded, groundingĆtype

receptacle, protected by a GroundĆFault

CircuitĆInterrupter (GFCI). Do not remove the

plug's ground pin. Do not use a grounding adapter.
Install to permit access for servicing.
Grounding is required. The unit should be

installed and grounded by a qualified service

representative.

INSTALLER HAZARD

NOTIFICATION

WARNING: Risk of electrical shock. A

licensed electrician should make all

electrical connections.
WARNING: Risk of electrical shock.

Disconnect power before servicing.
WARNING: Risk of injury or property

damage. Please read all instructions

thoroughly before beginning installation,

including the following requirements.

NOTICE:ĄFollow all local plumbing and

electrical codes.

FACTORYĆASSEMBLED FEATURES

FactoryĆinstalled components include a tower with

ten preĆassembled BodySpa jets and a waterfall, a

pump with integral heater, and a control.
The pump and most PVC piping connections are

factoryĆassembled. The pump kit consists of

components that require assembly, installation,

and sealing on the job site by a reliable, qualified

plumber.

PRODUCT MODIFICATIONS

WARNING: Unauthorized modification

may cause unsafe operation and poor

performance of the Custom BodySpa.

Do not remove the pump from the pump box

or make nonĆrecommended modifications to

the BodySpa system. Unauthorized

modifications could adversely affect the

performance and safe operation of the unit.

Kohler Co. shall not be liable under its

warranty or otherwise for personal injury or

damage caused by any unauthorized

modification.

PRODUCT INSPECTION

Carefully unpack and inspect the tower, pump

box, and suction bracket for damage. Return all

materials to the cartons during construction to

prevent damage.

CONNECTIONS AND SERVICE

ACCESS

Before installation, ensure proper access to the

final connections.
Install to permit access for servicing.
NOTICE:ĄProvide unrestricted service

access to the pump box. An access panel must

be constructed to allow for sufficient clearance for

servicing the pump and controls. The access panel

must be located immediately next to the pump

box. Refer to the Design Guide at the front of this

manual, and the stud framing preparation

requirements on Page 12.

ELECTRICAL REQUIREMENTS

The installation must have a Class A

GroundĆFault CircuitĆInterrupter (GFCI). The

GFCI protects against lineĆtoĆground shock

hazard. Use a 120 V, 20 A, 60 Hz dedicated service

for the BodySpa.