Inst alla tion, Check point #1, Room size and layout known – Kohler custom Bodyspa 116347-2 User Manual

Page 11: Provide 32 cu. ft. air space around pump box, Footbath basin size and shape known, Face and false wall locations known, Drain location known

Advertising
background image

116347Ć2Ć

AA

(A)

12

Kohler Co., Kohler, WI

STUD POCKET PREPARATION

NOTE: Carefully study the roughingĆin pages

located in the inside back cover pocket, and the

illustration at right before you begin construction of

the stud pocket. Follow the framing details carefully.
Use 2x4 framing for the stud pocket. Make sure you

allow for access to the pump in the event the

BodySpa requires service. Determine the drain

location.
We recommend a room size approximately 60Ćinches

long x 48Ćinches wide x 84Ćinches high for the

Custom BodySpa installation. The basin design must

provide for a water depth of at least 3Ćinches above

the top of the suction cover. This will allow an overall

basin depth of about 9Ćinches. The threshold of the

basin should be 6 to 7Ćinches above the top of the

suction cover. Construct the basin framing to result

in an overall basin water capacity between 90 and

200 gallons.

You must provide at least 32 cubic feet (length x

width x height) of unrestricted air space around

the pump box for the motor to cool properly and to

provide access to the pump. We suggest you

construct a false wall behind the face wall framing.

Locate the false wall along the tower wall.
For new installations, build this false wall so at

least 12Ćinches of access space exists to the back of

the face wall. For existing installations with

finished walls, or if separate access panels for the

pump, drain, water supplies, and suction assembly

are not feasible, provide more than 14Ćinches of

access space between the false and face walls so a

repair person can maneuver between the walls.
Carefully study the door enclosure installation

instructions packed with the door enclosure.

Construct suitable framing for the door enclosure,

including a header and support framing above the

doorway to prevent heat and moisture from

escaping. Remember to locate the door enclosure

perpendicular to the tower wall.
If you plan to install grab bars or other

accessories, provide sufficient backing.

Check Point #1

-

Room size and layout known.

-

Provide 32 cu. ft. air space around pump box.

-

Footbath basin size and shape known.

-

Face and false wall locations known.

-

Drain location known.