Inst alla tion, Check point #6, With outlet box, or – Kohler custom Bodyspa 116347-2 User Manual

Page 17: Without outlet box

Advertising
background image

116347Ć2Ć

AA

(A)

18

Kohler Co., Kohler, WI

Check Point #6

-

GFCIĆprotected electrical power supplied to pump box (120 V,

20 A).

-

Keypad cable installed and connected to the control box,

-

With outlet box, or

-

Without outlet box.

INSTALL WATERPROOFING

MEMBRANE OR COMPOUND

WARNING: Risk of property damage and

concealed leakage. To achieve a watertight

BodySpa installation, it is critical that you

install the waterproofing membrane or applied

compound according to the material

manufacturer's instructions. Kohler Co. will not

be liable for damage caused by waterproofing

materials that are improperly installed or

sealed.

NOTE: The waterproofing membrane or applied

compound and the cement board can be installed in

any order you prefer, as long as they are installed

exactly as directed. Follow all material

manufacturer's instructions.
Install a waterproofing membrane or applied

compound to the entire floor and wall surfaces (up to

the ceiling).
Although some membranes can be installed directly

to the stud framing, we suggest you install a plywood

backing behind the membrane at least to the height of

the basin threshold.

INSTALL SUCTION BUSHING

Use a 3Ć1/4Ćinch hole saw to carefully cut a hole in

the waterproofing membrane and plywood

backing at the suction inlet location.
Press the spacer fully into the suction housing

inlet.
Apply silicone sealant to the bushing flange

surface, and insert the bushing through the

suction hole. Partially thread the nut to the

bushing. Do not tighten. Apply silicone sealant to

the end threads of the bushing, and carefully

thread the bushing to the housing until hand

tight. Wrench tighten an additional 1/4 turn. Do

not overtighten. Wrench tighten the nut against

the plywood backing. Do not overtighten.

Remove any excess sealant.

INST

ALLA

TION

Advertising