TROUBLESHOOTING

SYMPTOMS

PROBABLE CAUSES

CORRECTIVE ACTION

BodySpa does not

start/stop

No power to pump/receptacle/keypad.

Set/Reset GFCI breaker; check wiring.*

start/stop.

Harness is blocked.

Remove blockage.*

Keypad disconnected from pump/control

box.

Reconnect keypad.

Keypad doesn't work.

Replace keypad.*

Circuit board doesn't work.

Replace circuit board inside control box.*

Motor/pump assembly doesn't work.

Replace motor/pump assembly.*

Not enough water in footbath basin.

Fill basin 3Ćinches over top of suction

cover.

Water flow surges.

Not enough water in footbath basin.

Fill basin 3Ćinches over top of suction

cover.

Suction is blocked.

Remove obstruction.

Harness is blocked.

Remove blockage.*

Motor starts, all Body

Jets are not functioning

Body Jet is blocked.

Remove blockage.*

Jets are not functioning.

Keypad doesn't work.

Replace keypad.*

Body Jet butterfly valve wiring loose or

damaged, or butterfly valve is faulty.

Identify source of fault and correct, or

replace faulty butterfly valve.*

Not enough water in footbath basin.

(Pump cavitates.)

Fill basin 3Ćinches over top of suction

cover.

Motor starts, Waterfall

does not function

Waterfall is blocked.

Remove blockage.*

does not function.

Keypad doesn't work.

Replace keypad.*

Waterfall butterfly valve wiring

loose/damaged - butterfly valve doesn't

work.

Identify source of fault and correct, or

replace faulty butterfly valve.*

Not enough water in footbath basin.

(Pump cavitates.)

Fill basin 3Ćinches over top of suction

cover.

Water flow increases

when B keypad button

is pressed - decreases

when Y button is

pressed.

Variable flow valve wiring error.

Reverse variable flow valve wire

connections.*

Waterfall light does not

ork

Light bulb is burned out.

Replace light bulb.*

work.

Loose or damaged wiring.

Identify source of fault and correct.*

BodySpa stops

automaticall before 18

GFCI trips.

Identify source of fault and correct.*

automatically before 18

minutes.

Motor overheated and protection device

activated.

Check for: restricted air space around

pump box; motor vent blockage;

suction/harness blockage. Correct and

allow motor to cool.*

BodySpa does not

automatically stop after

Timer mechanism doesn't work.

Replace timer board inside pump/motor.*

automatically stop after

22 minutes.

Wiring error.

Refer to dealer/installer.

Noisy operation.

Not enough water in footbath basin.

(Pump cavitates.)

Fill basin 3Ćinches over top of suction

cover.