Design guide – Kohler custom Bodyspa 116347-2 User Manual

Page 4

Advertising
background image

116347Ć2Ć

AA

(A)

Kohler Co., Kohler, WI

5

WIRING CONNECTIONS

WARNING: Risk of electrical shock. To

reduce the risk of electric shock, connect

only to a properly grounded, groundingĆtype

receptacle, protected by a GroundĆFault

CircuitĆInterrupter (GFCI). Do not remove

the plug's grounding pin. Do not use a

grounding adapter.

The Kohler Custom BodySpa is equipped with a

cord and plug. All wiring of the pump has been

completed at the factory. A licensed electrician

will need to install a GFCIĆprotected, 120 V, 20 A,

grounded outlet. The electrician must install the

outlet behind the BodySpa, and within 24Ćinches

of the pump. No other load should be on this

circuit.

SUCTION ASSEMBLY

The purpose of the suction bracket is to position the

suction housing at the correct installation height,

and to provide the installer with a means of

securing the suction housing in place during final

assembly. Do not remove the suction fitting from the

bracket assembly.
You can locate the suction along any wall of the

Custom BodySpa room within 48Ćinches of the

pump box, as long as the overall wall thickness will

not exceed 1Ć3/4Ćinches. Plan to provide access to

the suction assembly in case servicing is needed.

The suction location must allow the installer to

route straight lengths of 1Ć1/2Ćinch (I.D.) rigid PVC

tubing, with no vertical elbows inline to trap water,

from the suction housing to the pump inlet. You can

use a 90Ćdegree elbow at a wall corner if the suction

is located on a different wall than the pump box.
NOTE: Refer to the minimum waterline height

information on the side of the pump box to

determine the maximum pump box height needed

for the pump to prime effectively.
Plan to apply a minimum 1/4Ćinch per foot pitch

toward the suction housing to provide adequate

water drainage through the suction line.

DESIGN

GUIDE

Advertising