Inst alla tion, Check point #2, Plumbing supplies installed and capped – Kohler custom Bodyspa 116347-2 User Manual

Page 12: Tower mounting frame loosely mounted to studs

Advertising
background image

116347Ć2Ć

AA

(A)

Kohler Co., Kohler, WI

13

PLUMBING PREPARATION

NOTE: Locate the drain overflow so the PVC drain

pipe will not exceed 48Ćinches in length.
Position the plumbing supplies and drain trap

according to the roughingĆin dimensions and the

Custom BodySpa room design. Cap the supplies, and

check for leaks.

INSTALL THE TOWER MOUNTING

FRAME

On one of the tower mounting studs, draw a pencil

line exactly 18Ć5/8Ćinches up from the subfloor.

You will use this mark to temporarily position the

tower mounting frame at the correct height. Be

precise with this measurement.
Remove the three 3/8Ćinch tower bolts from the

locations shown, and carefully lift the tower out of

the mounting frame. Carefully set the tower aside

where it will not be damaged.
Position and level the mounting frame between

the tower mounting studs, and line up the bottom

metal edge with the pencil line you drew on one of

the studs.
Loosely hold the mounting frame to the stud

framing with four of the ten drywall screws

provided. Do not turn the screws all the way in at

this time.

Check Point #2

-

Plumbing supplies installed and capped.

-

Tower mounting frame bottom edge positioned 18Ć5/8Ćinches

above the subfloor.

-

Tower mounting frame loosely mounted to studs.

INSTALL THE PUMP BOX

The pump box contains a 2Ćhorsepower pump and

motor, along with the control box and an integral

heater.
Remove the suction bracket assembly from the pump

box. The suction bracket can later be installed in any

chosen location within 48Ćinches of the pump box.
Fit the pump box between the false wall and face

wall. Locate the pump box to maximize accessibility

and so the pump inlet faces in the direction of your

planned suction line. The pump box must be within

36Ćinches to either side of the tower so the tower and

Waterfall cables will reach to the pump box. Do not

secure the pump box in place at this time.

INST

ALLA

TION

Advertising