Setting the Scan Mode

The setting of scan mode can be set with Polygon Editing Tool software, and the setting is the top priority. It
is not required to set by VIVID 9i.
If you are not making scan settings from your PC’s software (for example, if using a customized program),
please make the settings at the digitizer itself.
Only settings are explained here.

N

ote

These settings become effective from the time of next start.

Item

Explanation

INITIAL MODE

Selects one of the preset scan modes.

DIGITIZE

Selects the scan mode.

• STANDARD: Allowable distance is 600 to 1000 mm.

The following initial conditions cannot be changed:
NOISE FILTER: ON; HIGH QUALITY: ON

• EXTENDED: Allowable distance is 500 to 2500 mm.

The following initial conditions cannot be changed:
NOISE FILTER: ON; HIGH QUALITY: OFF

• USER:

Allowable distance is 500 to 2500 mm.

Initial conditions can be changed as desired.

COLOR

Selects the color mode for image capture.

• ON:

Full color

• OFF:

No image

INITIAL CONDITION

Makes settings that are more detailed than the initial mode settings. Available set-

tings vary according to the selected initial mode.
Initial conditions that cannot be changed (as determined by the DIGITIZE scan

mode) are not displayed.

NUMBER OF
SCANS

Sets number of scans. Allows for increased dynamic range.

NOISE FILTER

If ON, noise filtering is applied to scan data.

HIGH QUALITY

If ON, unreliable scan data is discarded.

DARK

If ON, dark correction is applied to color data. Use this feature when you want to

remove the CCD offset components and get the signal components only. This set-

ting is not shown if INITIAL MODE-COLOR is set to OFF.>

LOG

If ON, log correction is applied to color data. Use this feature when you want to

brighten intermediate colors. This setting is not shown if INITIAL MODE-COLOR

is set to OFF.

STANDARD

3

HQ ON NF ON

COLOR OFF

W.B. DEFAULT

SCSI 5 ENABLED

WHITE BALANCE

INITIAL MODE

INITIAL CONDITION

SCSI SETTINGS

INFO

Vivid910-hard-E.book Page 46 Monday, October 18, 2004 3:11 PM