OPERATION OF THE SYSTEM

Service Handbook 08.2004

3.2.3

Antiscalant

The drinking water for the metering solution is taken from the sampling tap for drinking
water (1/4.21).

The antiscalant metering quantity can be set with a very good approximation using the following
table. The optimum quantity can only be calculated using a calculation program after a precise
water analysis has been carried out. The typical metering range lies between 2 and 5 mg/l.

Where water hardnesses are higher than 28°dH, special design is necessary.
If this design is not possible, the following setting is recommended: 5 mg/l RM5000 and 50%
yield, until the precise design is available.

Range of Water Hardness

Antiscalant [mg/l]

Metered

Run-down

amount of

Tank Service

RM 5000 [ml]

Life [h]

per 10 l
Metering
Solution

1 (0°-7° dH)

2,5

58

214

2 (7°-14° dH)

3

69

214

3 (14°-21° dH)

4

92

214

4 (21°-28° dH)

5

115

214

Table 10

Metering of antiscalant at 75% yield

Range of Water Hardness

Antiscalant [mg/l]

Metered

Run-down

amount of

Tank Service

RM 5000 [ml]

Life [h]

per 10 l
Metering
Solution

1 (0°-7° dH)

2,5

87

214

2 (7°-14° dH)

3

104

214

3 (14°-21° dH)

4

138

214

4 (21°-28° dH)

5

173

214

Table 11

Metering of antiscalant at 50% yield

1 °dH = 1,79 °frH

1 °dH = 17,9 mg CaCO3/l

1 °frH = 10,0 mg CaCO3/l