Karcher WATERCLEAN 600 CD User Manual

Page 35

Advertising
background image

35

WTC 600 LP / MP

OPERATION OF THE SYSTEM

Service Handbook 08.2004

3.4.3.4

Selecting Several Arguments at the Same

For this a series of “0” (argument inactive) and “1” (argument active) appears on the bottom line
of the display. With help of the

pushbutton and the

pushbutton, a cursor can be moved

between the individual characters. The activation / inactivation of an argument is carried out with
the pushbutton and the pushbutton respectively. Storing is carried out through pressing the
RETURN pushbutton (Example: See Chapter 3.4.3.7).

3.4.3.5

Adjusting Operating Parameters and Balancing Values

For adjustment of operating parameters (e. g. via a menu), the name of the operating parameter
appears in the upper line and the current value is shown in the bottom line. A flashing cursor
marks the respective changeable figure, which can be adjusted to the desired value by pressing
the pushbutton and the pushbutton. With help of the

pushbutton and the

pushbutton,

the marking can be slid to the respective other figure. Storing is carried out through pressing the
RETURN pushbutton; the input can be cancelled by pressing the ESC pushbutton.

3.4.3.6

Acknowledging Data Inputs

To avoid input errors, acknowledgments are required at various menu locations. They request
the user again to acknowledge changes of operational settings / parameters and adjustments as
correct.

For acknowledgment the

pushbutton and afterwards the RETURN pushbutton must be

pressed.

3.4.3.7

De-conserving

The RO system leaves the factory conserved. Therefore, the conservation liquid must be
flushed out before the initial startup.

Initial situation:
The pre-filters have been put into service. The filter insert has been inserted at the fine filter 5µ.
After all the water pipes and float switch have been connected, the drinking water pipe to the
tank must be undone and temporarily fed to the wastewater sewer.

Work steps:
- Master switch on: system is in switched off operating mode
- Temporarily lay the drinking water pipe in the sewer
- Flush / purge system:

- Pressure regulating valve (4.17) fully open (lever horizontal)
- Concentrate regulating valve (4.15) half open (45°).

The following message must be indicated on the display:

Otherwise press the ESC pushbutton 5 times.
Then enter user password (cf. Chap. 3.4.3.1).

RO 1000 V 01.34

Stop

Advertising