OPERATION OF THE SYSTEM

WTC 600 LP / MP

Service Handbook 08.2004

3.3

Connecting the Equipment

3.3.1

Connections, Valves and Indicators

Depending on the local untreated water supply, the WTC 600 LP/MP is connected directly to the
off-site supply or supplemented through a WTC 600 PI pressure-increase module.

The following constructional measures must be observed:

- The off-site untreated water supply must be equipped with a shut-off device (supplied by user

/ customer).

- All pipes / lines (untreated water, backwashing, concentrate and drinking water) to be installed

without mechanical tension.

- Drinking water line to be installed with free run-out and no further shut-off devices.

- Backwashing line to be installed with steady drop (under no circumstances inclined upward).

For easy and secure operation and main-
tenance of the system, minimum clearances
from the walls are to be observed:

Page

Minimum clearances [cm]

A

50

B

10

C

70

D

50

Table 12

Minimum clearances

Installation space (incl. working space for maintenance and operation, not including piping):
WTC 600 LP and MP: width x depth: 1300 x 1900mm
WTC 600 LP-A, LP-AM, MP-A, MP-AM: width x depth: 1700 x 1900 mm
WTC 600 CD: width x depth: 500 x 1100 mm
WTC 600 PI: width x depth: 600 x 200 mm

Figure 8

Minimum clearances WTC 600 LP/MP

Figure 9

Water connections, WTC 600 PI