MAINTENANCE

WTC 600 LP / MP

Service Handbook 08.2004

Replacing the membrane

- Set the pump lift adjustment knob (8/1) to 100 %.

- Unscrew the 4 screws, size 6 mm, at the metering head and remove the metering head.

- Unscrew the membrane to the left.

- Reattach the sealing membrane1), intermediate ring and support disc again.

- Screw in new membrane.

- Bring the push rod to the “end of suction stroke” position by switching the mains voltage on/

off.

- Reassemble metering head and tighten screws over cross (tightening torque 4 Nm).

- Bleed the pump (8/3) and put into operation again.

- After 48 hours of operation, retighten the metering head screws (tightening torque 4 Nm).

4.3

Reverse Osmosis Module (RO Module)

4.3.1

RO Filter Replacement

The RO filters are to be replaced when
cleaning and disinfection as a measure to
increase the capacity have been without
success.

Filter replacement:

- Select the switching off operating mode and

release the system pressure.

- Loosen the connections (concentrate

connection (18/2), drinking water connection
(18/1) and supply (18/5)) and unscrew
pressure tube (18/4) with tube clamps (19/5)
from the frame.

Do not loosen the tube clamps
because of height adjustment.

- Release securing rings (19/1).

- Unscrew connections (19/2).

- Screw extractor tool into thread of drinking

water connection (19/3) and carefully lever
out using pipe pliers.

- Remove adapter from lid, clean and insert.

- Take out filter and remove lower lid.

Do not interchange lids.

1)

Membrane replacement set: Item No. 6.762 172.0

Figure 18 RO-Modul