58

MAINTENANCE

WTC 600 LP / MP

Service Handbook 08.2004

4.5.3

Malfunctions of the RO Control and Metering Pump

Indication

Malfunction

Cause

Corrective Action

Chap./
Fig.

Indication of RO Fuse defective

Have replaced by

ETL,

control dark

electrician

diagram
in switch
cabinet

Short circuit,

Replace defective parts

general

Solenoid valve

Replace defective parts

ETL

defective

Motor winding

Replace defective parts

ETL

defective

Water level in

Pump does not

Suction line untight Retighten screwed

ETL

container is

draw in

fittings. Replace

constant for

suction line

days

Suction line

Flush or replace

clogged

suction line

Crystals, debris in Clean valves

4.2

the valves
(metering head)

Membrane torn or

Replace membrane

4.2

membrane push-
rod torn out

Pump does not

Air in the suction

Bleed pump

meter

line and in the
metering head

Lift adjustment a

While the pump is

zero

running, turn in “+”
direction (adjustment
values, see 3.3.1)

Crystals, debris in Clean valves

4.2

the valves
(metering head)

Valves not

Check correct line-up of

mounted correctly valves and correct,

if required (direction of
arrow!)

Injection fitting

Check direction of flow

blocked

and correct, if required,
or eliminate plug
(direction of arrow!)

Table 30

Advertising