Karcher WATERCLEAN 600 CD User Manual
Page 60
60
MAINTENANCE
WTC 600 LP / MP
Service Handbook 08.2004
4.6
Maintenance Plan
4.6.1
Maintenance During Operation
Module
Cycle / Time
Activity
Chap./Fig.
RO module: Flow meter
Daily
Check drinking water capacity
3.3.1.2,
(11/6)
RO module: Differential
Daily
Check pump and concentrate
(1/13)
pressure
pressure
(1/14)
RO control: Display
Daily
Check drinking water
(1/11)
conductance value
Metering container
Weekly
Check filling and refill
3.2
Media filter/activated carbon
Weekly
Automatic backwashing (check
3.4.2.4
filter
operation meter)
Control sheet
Weekly
Fill out
Appendix
Metering stations
Every 4 weeks Clean and flush metering
4.2
container
Float switch, drinking
Every 4 weeks Visual check of switch
water tank
Metering stations
Yearly or every Clean intake and pressure
4.2
4000 hours
valves
Metering stations
Yearly or every Replace membrane
4.2
4000 hours
Fine filter
Every 3
Replace filter
4.1
months
RO module (when conserved)
Every 6
Renew conservation
4.4.4
months
Tabelle 32