Mhz scan, Call scan – Kenwood TM-V71E User Manual

Page 56

Advertising
background image

48

MHz SCAN

MHz Scan monitors a 1 MHz segment of the band, using the current frequency

step size. The current 1 MHz digit determines the limits of the scan. For

example, if the current frequency is 145.400 MHz, then the scan range would be

from 145.000 MHz to 145.995 MHz (the exact upper limit depends on the current

frequency step size).
1 Select your desired band.
2 Press [VFO].
3 Rotate the Tuning control to select a frequency within your desired 1 MHz

range.

4 Press and hold the Tuning control for 1 second to start scanning.

• Scan starts at the current frequency.
• The 1 MHz decimal blinks while scanning is in progress.
• To reverse the scan direction, turn the

Tuning control clockwise (upward scan) or

counterclockwise (downward scan). You can also press microphone

[UP]/ [DWN].

5 To quit MHz Scan, press the Tuning control again.

CALL SCAN

Use Call Scan to monitor both the Call channel and either the currently selected

VFO frequency or the currently selected Memory channel.
1 Select your desired VFO frequency or Memory channel.
2 Press [CALL] (1s) to start Call Scan.

• The 1 MHz decimal blinks while scanning is in progress.
• When scanning a Memory channel, the Call channel on the same band as the

selected Memory channel is used for scan.

3 To quit Call Scan, press [CALL] again.

Note: The Memory channel selected is scanned even if it has been locked out of scan.

Advertising