KTI Networks KS-2601 User Manual

Page 9

Advertising
background image

5


2. If the switch is rack-mounted, you have to remove the switch from rack first.
3. Loosen the screws of the module with screwdriver. Two at the front side, one

at bottom side.

4. Remove the module slowly from the module slot.
5. Put on the module cover and fix it to the switch by driving its screws with

screwdriver. Two at the front side, one at bottom side.

6. If the switch is rack-mounted, you can put the switch back to rack.
7. Power ON the switch.


-- Modules at Rear Side --

[ Adding Module to the Switch at Rear Panel ]
1. Power OFF the switch first.
2. Loosen the screws of the cover on the module slot.
3. Remove the cover of the module slot.
4. Follow the rails on both sides of the module slot to slide in the module slowly.
5. Push the module firmly to make the module connecting well with the

connector in the switch.

6. Drive the screws to fix the module to the switch firmly.
7. Power ON the switch.
8. Connect network cables to the connectors on the module. If the connected

devices are working, the Link/Act LED will be ON.

Note: We suggest you to keep these removed module slot covers. It can be use
when these modules are removed in the future.

[ Remove Module from the Switch at Rear Panel ]
1. Power OFF the switch first.
2. Loosen the screws of the module.
3. Remove the module slowly from the module slot.
4. Put on the module cover and fix it to the switch by driving its screws.
5. Power ON the switch.

Rear Side

Module Slot

Advertising