Remote panels (optional), Remote start panel, Remote start and two-meter panel kit – Kohler 3.5CFZ User Manual

Page 27

Advertising
background image

TP-5695 12/93

2-6 Operation

Remote Panels (Optional)

Remote Start Panel

Remote start panel allows starting-stopping from a
location remote of the generator set. Generator sets are
equipped with a 6-pin connector on controller bottom for
connection of the kit. See Figure 2-5.

2

1

1. “ON”Light

2. Start/Stop Switch

1-656

KOHLER

GENERATOR

START

STOP

Figure 2-5. Remote Panel Features

Remote Start and

Two-Meter Panel Kit

Allows starting-stopping from a location remote of the
generator set. The illuminated gauges include an
engine oil pressure gauge and a water temperature
gauge. Generator sets come equipped with a 6-pin
connector on controller bottom for connection of the kit.
See Figure 2-6 for remote start and meter panel kit.

1

2

4

3

1. Engine Oil Pressure
2. Water Temperature

3. Start/Stop Switch
4. “On”Light

1-762

Figure 2-6. Remote Start and Two-Meter

Panel Features

Start/Stop Switch is a rocker-type switch with “ON”
light used to start and stop generator set.

Engine Oil Pressure Gauge measures engine oil
pressure. Normal engine operating range is 30--50 psi
(207--345 kPa).

NOTE

During the engine break-in period, it is normal for the
engine to produce higher oil pressure readings.

Water Temperature Gauge measures engine coolant
temperature. Normal engine operating range is
170--195_F (77--91_C).