Operation 2-7

Remote Start and Four-Meter

Panel Kit

Allows starting-stopping from a location remote of the
generator set. The illuminated gauges include a DC
voltmeter,

engine

oil

pressure

gauge,

water

temperature gauge, and generator running time
hourmeter. Generator sets come equipped with a 6-pin
connector on controller bottom for connection of the kit.
See Figure 2-7 for remote start and four-meter panel
features.

Start/Stop Switch is a rocker-type switch with “ON”
light used to start and stop the generator set.

DC Voltmeter measures voltage of starting battery(ies).
Normal battery operating range is 12--14 volts.

Engine Oil Pressure Gauge measures engine oil
pressure. Normal engine operating range is 30--50 psi
(207--345 kPa).

NOTE

During the engine break-in period, it is normal for the
engine to produce higher oil pressure readings.

Water Temperature Gauge measures engine coolant
temperature. Normal engine operating range is
170--195_F (77--91_C).

Hourmeter records total generator set operating hours
for reference in maintenance scheduling.

1

2

6

5

3

4

1. Engine Oil Pressure
2. Hourmeter
3. Voltmeter

4. Water Temperature
5. Start/Stop Switch
6. “ON”Light