Scheduled Maintenance 3-21

1. “Y ”Mark

2. “T”Mark

2

1

1-827

Figure 3-22. Determining Top Dead Center

1

2

3

1. Feeler Gauge
2. Adjusting Screw 3 mm

Square Head

3. Locknut; Use 9 mm

Wrench

1-831