Exhaust systems, General, Figure 6-16. mixer elbow/exhaust connection – Kohler 3.5CFZ User Manual

Page 71

Advertising
background image

TP-5695 12/93

Installation 6-9

TOTAL HOURS

0

0

0

0

0

1/10

10A

FUSE

BATT.

CHRG.

INPUT

NOTE

Use two hose clamps on each

end of all flexible exhaust

hose connections.

1. Exhaust Manifold
2. 3 ft. (1 m) Max.
3. Engine-Driven Seawater Pump
4. Heat Exchanger
5. Waterline

6. Seawater Strainer
7. Intake Strainer
8. Engine Coolant
9. Seawater

10. Seacock

11. Coolant Recovery Tank

1

2

3

4

5

6

7

8
9

10

11

STOP/START

258000-D

Figure 6-15. Closed/Heat Exchanger Cooling System

Exhaust Systems

General

Water-cooled exhaust lines should be used in all marine
installations. The hose used for the lines should have a
2 in. (51 mm) inside diameter. Keep the lines as short
and straight as possible. The use of two hose clamps on
each end of flexible exhaust hose connections is highly
recommended. ABYC Safety Standards P-1.6.c
recommend a pitch of at least 1/2 in. (12.8 mm) per
running foot (30.5 cm). Use flexible steam hose
conforming to UL Standard 1129 for “Engine wet
exhaust components” between the mixing elbow and
the exhaust outlet. A silencer should be independently
mounted to eliminate any stress on the exhaust system
and exhaust manifold/mixer elbow. See Figure 6-16 for
the exhaust connection to the mixer elbow.

1

1-894

1. Seawater/Exhaust Outlet

Figure 6-16. Mixer Elbow/Exhaust Connection

Advertising
This manual is related to the following products: