ADJUSTABLE PARAMETERS

The Room EQ Setup accesses the Digital Room Equalizer, a feature
designed by Krell to provide every adjustment from simple bass and
treble to comprehensive room correction. The Digital Room
Equalizer enables you to adjust frequency response through three
discrete bands (I, II, and III). The four adjustable parameters available
are filter type, frequency, shape, and level.

There are four Room EQ setup memories, each of which saves
every parameter set for every filter, for every channel. Each setup
memory can save a configuration, for example, one for stereo
music, one for multichannel music, one for movie surround, and one
for video game software.

You can adjust the filters for S–1000 channels globally or individual-
ly. Up to three filters can be configured to act equally on all seven
channels of audio. Alternatively, each filter can be configured sepa-
rately for each individual channel.

TYPE

Six filter types are available for each filter: Notch Filter, Peaking Filter,
High Shelf Filter, Low Shelf Filter, High Pass Filter (HPF) and Low
Pass Filter (LPF). Each of the filter types available has a unique
effect on frequency response.

The following three parameters for filters may be configured,
depending on the filter type selected:

FREQ

The center/cutoff frequency can be specified for all six filter types,
from 20 Hz to 16 kHz in 1/3 octave increments.

SHAPE

Shape controls the bandwidth of the filter and is adjustable on the
Notch and Peaking filter types, from 0.4 to 9 octaves. Shape is fixed
at a 6 dB / octave slope for the High and Low Pass Filters. This
parameter is not available for the High and Low Shelf Filters.

LEVEL

Level is adjustable on the Peaking, High Shelf and Low Shelf filters,
from -12 dB to +6 dB. Level is fixed for the Notch Filter at - 90 dB.
This parameter is not available for the High and Low Pass Filters.

Krell S–1000

53

HOW TO NAVIGATE
IN THE MENU MODE

1 Press the menu key (29) to enter and

exit the menu mode from the

operational mode.

2 Press the direction keys (33) to scroll

from line to line, and to scroll through

options within a line.

3 Press the enter key (32) to select and

set an option.

4

Use the directional keys to scroll to

the next line.

5

Press the prev key (30) to return to the

previous screen.

6 Press the pre key (1) to exit the menu

mode and place the S–1000 in the

stand-by mode.