Lexmark 5021-0XX User Manual

Page 83

Advertising
background image

Diagnostic information

2-5

5021-0XX

946

Engine controller
hardware error

Turn power off and then back on.

If error still exists, replace engine controller board.
Go to

“Engine controller board removal” on

page 4-55

.

947

Process timing clock
error

Indicates synchronization signal from main motor
(MM) is not inputted.

Go to

“911—Main motor service check” on

page 2-48

.

953

NVRAM chip failure

Indicates engine board NVRAM failed.

Replace engine controller board. Go to

“Engine

controller board removal” on page 4-55

.

954

NVRAM CRC failure

Indicates the operator panel failed CRC check.

Replace the operator panel cable. Go to

“Operator

panel cable removal” on page 4-54

.

955

Code CRC

Indicates that on-board NAND flash located on RIP
board has failed CRC check. Replace RIP board. Go
to

“RIP board removal” on page 4-45

.

955

Code ECC

Indicates that on-board NAND flash located on RIP
board has failed CRC check. Replace RIP board. Go
to

“RIP board removal” on page 4-45

.

956

Processor failure

Indicates a problem with RIP board processor.
Replace RIP board. Go to

“RIP board removal” on

page 4-45

.

957

ASIC failure

Indicates a problem with RIP board ASIC. Replace
RIP board. Go to

“RIP board removal” on

page 4-45

.

958

NAND failure

Indicates that on-board NAND flash located on RIP
board has failed. Replace RIP board. Go to

“RIP

board removal” on page 4-45

.

959

SRAM failure

Indicates a problem with RIP board SRAM. Replace
RIP board. See

“RIP board removal” on page 4-45

.

960

Memory error

Indicates that RIP board soldered RAM is bad.
Replace RIP board. Go to

“RIP board removal” on

page 4-45

.

Error code

Action

Advertising