Lucent Technologies CELLPIPE 7820-0766-004 User Manual

Page 32

Advertising
background image

Configuring a 20 Series CellPipe
Configuring WAN interface

4-6

CellPipe™ 20 Series User’s Guide

Select the

rx_bin

command to limit the bin number used for special configurations

in the receive signal. Values for bin numbers are between 1 to 255.

>adsl> rx_bin - <start_bin> <end_bin>

Select the

show

command to display the ADSL parameter configuration. For

example:

>adsl> show

ADSL setting:

Current

Ineffective

Local line code

MULTIMODE

MULTIMODE

Trellis encoding

Enabled

Enabled

EC/FDM mode

FDM

FDM

Coding gain

AUTO

2 dB

Transmit Power Attenuation 0 dB

0 dB

Tx Start bin

6 (H)

6 (H)

Tx End bin

1f (H)

1f (H)

Rx Start bin

20 (H)

3 (H)

Rx End bin

ff (H)

4 (H)

Select the

startup

command to restart the ADSL connection.

>adsl> startup

start to re-Sync. ...

Select the

status

command to display the ADSL parameter configuration. For

example:

>adsl> status

ADSL Firmware version ANNEX_A CPE 41000

OP state handshake

Last Failed Status (0)

Start Progress a0

Watchdog Timer 53

Line code

G.DMT

Framing_Overhead_actual 0

Trellis

<disable>

AS0_Dn_Bytes_Actual 0