Upgrading System Software
Upgrading software

5-2

CellPipe™ 20 Series User’s Guide

Upgrading software

Follow the procedure below to upgrade software:

1

Extract the loads from eSight to your computer.

2

Establish an Ethernet connection between the unit and your computer.

3

Set up IP addresses on the unit and your computer such that you can successfully
ping the unit.

4

Under the DOS prompt on your computer, enter the path to the directory
containing the extracted loads and a file named xupgrade.bat.

5

To start the upgrade, execute command

xupgrade <ipaddress of

unit>

, for example:

C:\>

xupgrade 149.198.65.46

Note:

There is no need to back up your current configuration. Using the

xupgrade.bat file for upgrading will retain your current configuration. The
upgrading process might last as long as 60 seconds.

6

Then enter the

restart

command to reboot the unit.

7

Lastly enter the

save

command to save the new upgrade.

Note:

Maintain stable power to the unit while upgrading software. If power fails

during the upgrading process, contents in the memory could be destroyed and the
system will hang and no longer function.