Troubleshooting

RoomPerfect™

No microphone connected

The error message ‘No microphone connected’ is displayed when no microphone is connected to the

RP-1.

Solution:

• Connect the microphone on the back panel.

No signal

1. The error message ‘Fault – No signal’ is displayed when the incoming signal is classifi ed as

pure noise. This happens when the RP-1´s measuring signal is too low compared with the noise

from the local environment.

2. The volume setting of your amplifi er and/or RP-1 measuring volume is to low.

3. The above error message is also displayed when the loudspeakers are not connected.

Solution:

• Reduce the noise in your measuring environment.

• Raise the volume setting of your amplifi er and/or RP-1 measuring volume before continuing with the

measurement.

• Connect your loudspeakers.

Low signal

The error message ‘Fault – Low signal’ is displayed when the measurement has taken more than 5

minutes for the low frequency signal or 2 minutes for the high frequency signal. This happens when

the system calibration volume is low compared to the background noise of your environment, some-

thing that results in prolonged measuring times.

Solution:

• Raise the RP-1´s measuring volume or the volume setting of your amplifi er before continuing with

the measurement, or reduce the noisy elements in your environment.

Signal clipping

1. The error message ‘Fault – Signal clipping’ is displayed when the incoming signal is

classifi ed as too loud resulting in clipping (distortion).

2. A loud noise from the local environment that has corrupted the measurement results in this

error message.

Solution:

• Lower the measuring signal volume before continuing with the measurement.

• Repeat the measurement with no changes; however refrain from making excessive noise

when measuring.