ACCESSORIES

C-5

C-5

LN-25™

K439 REMOTE EXTENSION CABLE
ASSEMBLY

The 50 ft. Extension cable assemblies are used to ex -

tend the K432 Remote Control Cable Assembly when

longer cable lengths are required.

Multiple K439 Extensions may be used, however, to

prevent excessive weld cable voltage drops, the 500

amp max. rating of the K432 should be reduced by at

least 50 amps for each K439 Extension used. For

example, if three K439 Extensions are used (150 ft

total extension), the maximum welding current used

should be less than 350 amps.

The K439 Extension cable end with the male pin con -

nector connects to the K433 Remote Box and power

source per the Instructions included with the K433 kit.

The K439 Extension cable end with the socket pin

connector connects to the mating K432 cable end (or

next K439 Extension cable end). The electrode cables

are connected using the bolt and nut provided with

the K439 Extension. Properly insulate the bolted con -

nection with electrical tape.

K624-1 42V REMOTE OUTPUT
CONTROL MODULE

( F o r u s e w i t h K 6 2 5 , K 6 2 6 , K 6 2 7 R e m o t e

Control Cable)

The Module includes a 42V Remote PC board and

control cable receptacle which mount and connect

inside the LN-25™ control box per the Installation

Instructions included with the kit.

NOTE: If the K624-1 42V Remote Output Control
Module is installed but the LN-25™ is to be used

without the K625, K626 or K627 Remote Control

Cable Assembly, then the Remote Board harness plug

must be removed from the 16-pin receptacle on the

Control Board and the jumper plug (T13498-21)

reinstalled.

K625, K626, K627 REMOTE CONTROL
CABLE ASSEMBLY

(Requires K624-1 Remote Output Control Module

installed in LN-25™.)

The K625, K626, K627 control cable assemblies

include an electrode cable and a 8-conductor control

cable:

The cable assembly end with the socket pin connector

connects to the LN-25™ per the Instructions included

with the K624-1 Kit.

The cable assembly end with the male pin connector

connects to the power source per the Instructions

included with the K624- 1 kit.

K444, K444-1 OR K444-2 REMOTE
VOLTAGE CONTROL KIT

(Not required if using K431-1 or K624-1 Remote

Output Control Kit.

The Remote Voltage Control Kit provides remote (10K

ohm rheostat) control of power source output arc

voltage level.

K444 connects to power sources with control terminal
strip connections for lead numbers 75, 76 and 77.

K444-1 connects to power sources with a 6-pin control
receptacle.

NOTE: To use a K444-1 with power sources with only
a 14-pin control receptacle, a K864 Adapter is required

to connect to K444-1 and if using a power source

without an output control switch, a K484 Jumper Plug

will also be required to jumper the output pilot circuit

(2-4).

K444-2 connects to power sources with a 14-pin
control receptacle and provides a 2-4 jumper to

activate power source output.

Installation Instructions are included with the kit.

K577-1 REAR HANDLE KIT

(For LN-25™ model codes above 9383)

The fold-down handle mounts to the rear of the LN 25

case per the Installation Instr uctions (M16567)

shipped with the kit.

This handle provides a means to also carry the LN 25

in the ver tical position, especially convenient for

passing the unit through a manhole.

CABLE

60% DUTY

POWER SOURCE

TYPE

RATING

ELECTRODE

CONNECTION

K625

500 Amps

Stud Terminal

K626

350 Amps

Stud Terminal

K627

400 Amps

Twist-Mate™

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Advertising