GAS SOLENOID VALVE AND CONTROL PC BOARD TEST

(FOR CODES ABOVE 10500 ONLY)

(continued)

FIGURE F.7. – APPLIED VOLTAGE POLARITY.

WORK SENSING LEAD

POLARITY
SWITCH

ELECTRODE
CABLE

CONTROL PC BOARD SOLENOID CIRCUITRY
TEST

1. Apply at least 25 VDC but no more than 100

VDC to the LN-25™ from the electrode cable to

the work sensing lead. Make sure the polarity

sw i t c h i s s e t t o m a t c h t h e p o l a r i t y o f t h e

electrode cable. For example, if the electrode

cable is positive and the work sensing lead is

negative, set the polarity switch to positive. See

Figure F.7.