Troubleshooting and repair – Lincoln Electric LN-25 SVM114-C User Manual

Page 49

Advertising
background image

TROUBLESHOOTING AND REPAIR

F-11

F-11

LN-25™

2. C h e ck fo r t h e p r e s e n c e o f t h e D C vo l t a g e

applied from lead 624A(+) to lead 621(-). See

Figure F.4

3. Check for the presence of 12 VDC from lead

512(+) to lead 621(-).

4. Check for the presence of 10 VDC from lead

606(+) to lead 621(-). When the LN-25™ trigger

circuit is activated, the voltage should drop to

about 1 VDC.

5. If the above voltage readings are good and the

solenoid valve is functional, the Solenoid PC

Board may be faulty.

6. If the above voltage checks are not correct, the

control board, contactor board (if used), remote

control board (if used) and/or wiring harness

may be faulty. Refer to the wiring diagrams in

the Electrical Diagrams Section.

The appropriate jumper plugs may be used to

isolate and check suspect contactor or remote

control boards.

GAS SOLENOID VALVE AND SOLENOID PC BOARD TEST (continued)

FIGURE F.4 – PC BOARD FOR K430-1 GAS SOLENOID KIT.

PC BOARD FOR K430 GAS SOLENOID KIT.