Calibration of ln-25™ wire speed dial, Maintenance, Warning – Lincoln Electric LN-25 SVM114-C User Manual

Page 31

Advertising
background image

MAINTENANCE

D-3

D-3

LN-25™

Proper positioning of this module is critical to proper

operation of the LN-25™ wire feed speed control. If

the device is not screwed in far enough, the LN-25™

motor speed could be unstable or run at full speed

with no control. If screwed in too far, it will rub a

moving part inside the gearbox.

The module is proper ly mounted to the gearbox

as shipped from the factory. If the device is ever

re moved or replaced, proper mounting technique is as

follows:

1. Be sure all power to the LN-25™ is shut off at the

power source.

2. Check that the module mounting plate is screwed

securely to the side of the gearbox. Refer to Drive
Motor and Gearbox Replacement Procedure
and access to the Hall Effect Module in the
Troubleshooting and Repair Section.

3. Gently screw the module into the mounting plate

until it just touches and stops against the rotating
part inside the gearbox.

4. Back the module out

1

2

turn, then snug the module

lock nut without rotating the module position. Do

not over tighten lock nut.

CALIBRATION OF LN-25™ WIRE
SPEED DIAL

Calibration of the LN-25™ Wire Speed dial is achieved

by proper mounting of the dial knob to the speed

potentiometer shaft. Whenever the knob is removed,

the dial is recalibrated as follows:

NOTE: Knob set screw does not seat on shaft flat.

1. Be sure the Wire Speed potentiometer mounting

nu t i s s e c u r e l y t i g h t e n e d , t h e n r o t a t e t h e

potentiometer shaft so its flat faces about to the

100 mark on the LO range calibrated dial.

2. Set DIAL RANGE switch to LO and WIRE FEED

MODE switch to CV position.

3. P r e s s g u n t r i g g e r t o fe e d w i r e a n d m e a s u r e

the wire feed speed (IN/MIN) using a Por table

Digital Wire Feed Speed Meter (Lincoln K283).

Take at least two readings to assure repeat-

able accuracy.

Electrode will be electrically “hot”. Do not allow fed

wire to contact any metal common with welding work.

An alternate means to measure wire feed speed

is as follows:

a. Cut wire off at the end of the gun tip.

b. Press trigger to feed wire for exactly 30 seconds.

c. Cut fed wire off at the end of the gun tip and

accurately measure its length.

d. Multiply the measured length by 2 to obtain

the wire speed (IN/MIN).

e. Repeat above steps to assure repeatable

accu racy.

4. Carefully slip speed knob onto potentiometer

shaft so it points precisely to the wire speed

measured in step 3, then secure the knob set

screw without disturbing the position. Recheck by

repeating step 3.

WARNING

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Advertising