Troubleshooting and repair – Lincoln Electric LN-25 SVM114-C User Manual

Page 47

Advertising
background image

TROUBLESHOOTING AND REPAIR

F-9

F-9

LN-25™

3. Locate and remove the two solenoid leads from

the solenoid valve (For codes 9812 and below,

remove the two leads from the Solenoid PC

Board). See Figure F.2.

4. Make sure the gas supply for the solenoid is

hooked up, and then apply 12 VDC to the gas

solenoid.

5. If the solenoid activates and allows gas flow,

then the solenoid valve is good.

NOTE: There should not be any gas flow until the
solenoid is activated.

6. If the solenoid does not activate and allow gas

to flow, then the solenoid is faulty. Replace.

7. T h e

n o r m a l

s o l e n o i d

r e s i s t a n c e

i s

approximately 20 to 27 ohms.

GAS SOLENOID VALVE AND SOLENOID PC BOARD TEST

(continued)

FIGURE F.2 – SOLENOID LEADS.

SOLENOID LEADS

SOLENOID LEADS