REPAIR PROCEDURE

1. O b s e r ve t h e s t a t i c e l e c t r i c i t y p r e c a u t i o n s

d e t a i l e d

i n

P C

B o a r d

Tr o u bl e s h o o t i n g

Procedures at the beginning of this section.

2. Open the case door. Remove the wire reel by

removing the retaining collar. See Figure F.5.

3. Remove the screws holding the control box

cover in place and remove the control box

cover. See Figure F.5.

4. For codes 10148 and above, remove the four

plugs J1, J2, J3 and J4. See Figure F.20.

5. For codes 9812 and below, remove the four

plugs J1, J2, J3 and J4. Also, tag and remove

the five individual leads (three hall effect leads

500, 512 and 555 and two drive motor leads

5 3 9 a n d 5 4 1 ) c o n n e cte d to th e c o n tro l P C

board. See Figure F.21.

NOTE:For Codes above 10148 with newer Control

Board (L12253-[ ]) and a contactor, remove
plug J14. See Figure F.22.

6. On older codes, the control PC board is larger.

It may be necessary to remove the Contactor

PC Board or the Remote Control PC Board if

installed.

CONTROL PC BOARD REPLACEMENT (continued)

FIGURE F.20. – CONTROL PC BOARD PLUG LOCATIONS (CODES 10148 AND ABOVE).

J4

J3

J1

J2

G2196

G2196

539

541

512

555

500

G1757

G1757

FIGURE F.21. – CONTROL PC BOARD (CODES 9812 AND BELOW).

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Advertising