Troubleshooting and repair, Control pc board replacement (continued) – Lincoln Electric LN-25 SVM114-C User Manual
Page 74
TROUBLESHOOTING AND REPAIR
F-36
F-36
LN-25™
REPAIR PROCEDURE
1. O b s e r ve t h e s t a t i c e l e c t r i c i t y p r e c a u t i o n s
d e t a i l e d
i n
P C
B o a r d
Tr o u bl e s h o o t i n g
Procedures at the beginning of this section.
2. Open the case door. Remove the wire reel by
removing the retaining collar. See Figure F.5.
3. Remove the screws holding the control box
cover in place and remove the control box
cover. See Figure F.5.
4. For codes 10148 and above, remove the four
plugs J1, J2, J3 and J4. See Figure F.20.
5. For codes 9812 and below, remove the four
plugs J1, J2, J3 and J4. Also, tag and remove
the five individual leads (three hall effect leads
500, 512 and 555 and two drive motor leads
5 3 9 a n d 5 4 1 ) c o n n e cte d to th e c o n tro l P C
board. See Figure F.21.
NOTE:For Codes above 10148 with newer Control
Board (L12253-[ ]) and a contactor, remove
plug J14. See Figure F.22.
6. On older codes, the control PC board is larger.
It may be necessary to remove the Contactor
PC Board or the Remote Control PC Board if
installed.
CONTROL PC BOARD REPLACEMENT (continued)
FIGURE F.20. – CONTROL PC BOARD PLUG LOCATIONS (CODES 10148 AND ABOVE).
J4
J3
J1
J2
G2196
G2196
539
541
512
555
500
G1757
G1757
FIGURE F.21. – CONTROL PC BOARD (CODES 9812 AND BELOW).