TROUBLESHOOTING AND REPAIR

F-20

F-20

LN-25™

TEST PROCEDURE

1. Open the case door. Remove the wire reel by

removing the retaining collar. See Figure F.5.

2. Remove the screws holding the control box

cover in place and remove the control box

cover. See Figure F.5.

3. Locate the three hall effect leads 500, 512 and

555 incor porated in plug J4 on the Control

Board (for codes 9812 and below, the leads

connect directly to the Control Board). Do not

disconnect the leads from the

board. See

Figure F.9, or F.10. See Figure F.11 for codes
above 10500.

HALL EFFECT MODULE TEST (continued)

FIGURE F.9 – CONTROL PC BOARD (CODES 10148 THRU 10500).

FIGURE F.10 – CONTROL PC BOARD (CODES 9812 AND BELOW).

J4

J3

J1

J2

541

539

555

541

539

555

500

512

G2196

G2196

539

541

512

555

500

G1757

G1757